Showing all 10 results

AC Drive (Variable Speed Drives)-VSD

Application of Simple & High Complex Machines 0.18 to 15 KW 18.5 KW to 700 KW Input Voltage : 110 to 600 VAC
  • Open: Large Number of Options
  • User-Friendly Interface
  • Autotuning for Maximum Performance
  • Standards:  IEC/EN61800-5-1, IEC/EN61800-3, (environments 1 and 2)
  • Quadratic ratio of Control
  • Integrated EMC Filter
  • Support Up to 200m of cable Length
  • Reduction of Current Harmonics Better continuity of service Wide range of Functionality.
 

Air Circuit Breaker-ACB

Air circuit breaker is an automatically operated electrical switch that uses air protect an electrical circuit from damage caused by excess current from an overload or short circuit.
  • Fixed and Withdrawable Type
  • 3P/4P, Fixed/Draw Out, Manual Electrical Versons
  • Circuit Breaker & Switch disconnector Versons Compliance With International Standards IEC, UL489 & ANSI/UL106 CCC and GOST certifications
  • Micrologic Controle Units With Current, Power & harmonics metering
  • Get an air circuit breaker (ACB) that operates in the air as an are extinguishing medium at given atmospheric pressure.
  • It's primary function is to interrupt current flow at after a fault is defected. When this happens an are will appear between the contacts that have broken the circuit.

Industrial Dol Starters

A DOL Starter (also known as a direct online starter or across-the-line starter) is a method of starting a 3-phase induction motor. In a DOL Starter, an induction motor is connected directly across its 3-phase supply, and the DOL Starter applies the full line voltage to the motor terminals. Range : 0.25 KW to 7.5 KW Degree of Protection : IP 6 Industry, infrastructure, buildings, etc. All machines requiring: DOL motor starting or stopping simple soft starting overload protection.

Industrial Soft Starters

Electrical Soft Soft Starter Range : 5.5KW to 700KW Input Voltage: 110 to 500 VAC
  • Designed for 3-phase AC motors And Harsh Application (Srt tm >30s
  • Patented torque Control system Manage Soft Starting and Dynamic Breaker
  • Machine Under and Overload Protection
  • Integrated Modbus and Other Gateway Solution.
 

Load Break Switch (LBS)

We are a most trusted name in between the topmost companies in this business, involved in providing Load Break Switch (12 KV LOAD BREAK SWITCH 630A 26.3A) Feature :
  • Safe in Use
  • Defect Free

Magnetic Contactors – MC

Magnetic Contactors offers you quick simple setup, while maintaining a compact size of 45 (9 to 38 A) AND 55MM (40-65A) as will as compliance with international standards. From 40 to 65 Versions are equipped.
  • Safe and long lasting power connection with ever link & spring .
  • 9 ratings between 185 & 800 A (400 V, AC-3)
  • 9 ratings between 200 & 1600 A (400 V, AC-3)
  • All in one size:
  • 6,9,12 & 16 A : 2.2, 4, 5 & 7.5 KW
  • Accessories for the above
  • Recognized high performances and quality solutions.
  • Outstanding breaking/making capacity up to 20In.
  • Multi standard: IEC, UL Marine etc.
  • World wide availability of products and after sales services.

Metering Product

These compact meters help ensure the reliability and efficiency of your facility by making the management of power quality, availability, and reliability and easy. Measure, understand, and act on insightful power and energy data gathered from your entire system. Address power issues before they cause problems
  • Monitor harmonics to mitigate excessive heating and premature failure of transformers
  • Use trending and alarming to detect fluctuations in current pull of critical equipment to prevent motor failure
  • Utilize millisecond time stamping to analyze sequence of events
  • Identify root cause by analyzing electrical faults with patented disturbance direction detection
  • Identify power quality issues per EN 50160, including frequency inconsistency, voltage fluctuations and unbalance, and harmonic contribution
  • Allocate costs for water, air, gas, electricity, and steam (WAGES) across departments, phases of industrial process, or cost centers
  • Utilize time-of-use calendar to capture electrical consumption for specific times, including on/off peak and holidays.
  • Measurement of 3 phase current, 6 step voltage, KW, KWH, KVA, KVAH, KVAR & KVARH, Measurement of THD and PF, Integrated RS485 port and Modbus protocol, and Digital output.

Motor Protection Circuit Breakers (MPCB)

Manual motor starters, also known as motor protection circuit breakers (MPCBs) or manual motor protectors (MMPs), are electromechanical protection devices for the main circuit. They are mainly used to switch motors ON/OFF manually and to provide fuse less protection against short-circuit, overload and phase failures. Fuse less protection saves costs, space and ensures a quick reaction under short-circuit condition by switching the motor off within milliseconds. Starter combinations are setup together with Contactors and are available with screw or Push-in Spring terminals.
  • Main accessory range (auxiliary contacts, signal contacts, shunt trips and under voltage releases)
  • Compact design with unique, fast, easy and reliable connections
  • Simple connecting links ensure electrical and mechanical connection to build direct-on-line starters
  • Less machine downtime by protecting motors and reduced trouble shooting and reduced maintenance expenditures by protecting motors.
  • Thermal and short circuit protection- Icu 10 KA or 50 KA
  • Thermal and short circuit protection- Icu 35 KA, 50 KA & 100 KA
  • Thermal and short circuit protection- Icu 70 KA Protection from short circuits and Over Loads.
  • Emergency stop switch (special version)

Protection Device-RCCB/RCBO/ELCB/SPD/RCD

Achieve full coordination with MCB's with DIN rail RCCB you can relay on. Providing better continuity of service as well as operating a complete environmentally friendly option, the DIN rain RCCB will also give you additional protection against any defect contact.
  • Adaptable to all common voltages Test button
  • LED (optional)
  • Nominal current 1 to 100A
  • 30mA, sensitivity: Provides additional protection against direct contact (in accordance with IEC 60364)
  • Relay state mechanical indication 100mA, 300mA, 500mA sensitivities: Provide additional protection against fire & indirect contact (in accordance with IEC 60364)

Vacuum Circuit Breaker-VCB

A vacuum circuit breaker is such kind of circuit breaker where the arc quenching takes place in vacuum. The technology is suitable for mainly medium voltage application. Advantage: Vacuum circuit breaker does not require any additional filling of oil or gas. The do not need periodic refilling. Rapid recovery of high dielectric strength on current interruptions that only a half cycle or less arcing accurse after proper contact separation.
  • (12KV to 36KV)
  • Operates up to 40.5KV
  • Withdrawable or Fixed versions
  • Embedded pole Design
  • Short-circuit current up to 50 KA
  • Safe: Highly Visible mechanical indicators, No hazardous tripping, Comprehend.
  • Convenient: Usage for all application in medium voltage, Compact Dimensions.
  • Easy to integrate into any Panel, Easy to operate, Well suited for retrofit.
  • Limited Maintenance
  • Extremely resistant to harsh environment due to embedded pole construction: Robust Construction: High mechanical stability versus Vibration, Altitude and Temperature.
  • Environmentally Friendly with no harmful gas or oil interrupting media.