Showing 73–78 of 78 results

LV432894

Original price was: 92,000.00 ৳ .Current price is: 64,400.00 ৳ .
Moduled Case Circuit Breaker Compact NSX630N, 50 kA at 415 VAC, Micrologic 2.3 trip unit 630 A, 4 poles. This

Magnetic Contactors – MC

Magnetic Contactors offers you quick simple setup, while maintaining a compact size of 45 (9 to 38 A) AND 55MM (40-65A) as will as compliance with international standards. From 40 to 65 Versions are equipped.
  • Safe and long lasting power connection with ever link & spring .
  • 9 ratings between 185 & 800 A (400 V, AC-3)
  • 9 ratings between 200 & 1600 A (400 V, AC-3)
  • All in one size:
  • 6,9,12 & 16 A : 2.2, 4, 5 & 7.5 KW
  • Accessories for the above
  • Recognized high performances and quality solutions.
  • Outstanding breaking/making capacity up to 20In.
  • Multi standard: IEC, UL Marine etc.
  • World wide availability of products and after sales services.

Metering Product

These compact meters help ensure the reliability and efficiency of your facility by making the management of power quality, availability, and reliability and easy. Measure, understand, and act on insightful power and energy data gathered from your entire system. Address power issues before they cause problems
  • Monitor harmonics to mitigate excessive heating and premature failure of transformers
  • Use trending and alarming to detect fluctuations in current pull of critical equipment to prevent motor failure
  • Utilize millisecond time stamping to analyze sequence of events
  • Identify root cause by analyzing electrical faults with patented disturbance direction detection
  • Identify power quality issues per EN 50160, including frequency inconsistency, voltage fluctuations and unbalance, and harmonic contribution
  • Allocate costs for water, air, gas, electricity, and steam (WAGES) across departments, phases of industrial process, or cost centers
  • Utilize time-of-use calendar to capture electrical consumption for specific times, including on/off peak and holidays.
  • Measurement of 3 phase current, 6 step voltage, KW, KWH, KVA, KVAH, KVAR & KVARH, Measurement of THD and PF, Integrated RS485 port and Modbus protocol, and Digital output.

Over Load Relays

Overload relay is one such devices that protects a motor from damages caused due to overloads and over-currents. It is used with contactors and can be found in motor control centers and motor starters. 3 Models: Overload relays available in class 10 and class 20 version, Compact design in 45 mm width for LRD relays up to 38 A, Direct mounting on contactor is possible, Accessories are available to mount relays independently, Easy fault indication by LED is possible in EOCR, Wide variety of accessories like  remote reset cord, extended STOP PB is available for quick installation.

Protection Device-RCCB/RCBO/ELCB/SPD/RCD

Achieve full coordination with MCB's with DIN rail RCCB you can relay on. Providing better continuity of service as well as operating a complete environmentally friendly option, the DIN rain RCCB will also give you additional protection against any defect contact.
  • Adaptable to all common voltages Test button
  • LED (optional)
  • Nominal current 1 to 100A
  • 30mA, sensitivity: Provides additional protection against direct contact (in accordance with IEC 60364)
  • Relay state mechanical indication 100mA, 300mA, 500mA sensitivities: Provide additional protection against fire & indirect contact (in accordance with IEC 60364)

Vacuum Circuit Breaker-VCB

A vacuum circuit breaker is such kind of circuit breaker where the arc quenching takes place in vacuum. The technology is suitable for mainly medium voltage application. Advantage: Vacuum circuit breaker does not require any additional filling of oil or gas. The do not need periodic refilling. Rapid recovery of high dielectric strength on current interruptions that only a half cycle or less arcing accurse after proper contact separation.
  • (12KV to 36KV)
  • Operates up to 40.5KV
  • Withdrawable or Fixed versions
  • Embedded pole Design
  • Short-circuit current up to 50 KA
  • Safe: Highly Visible mechanical indicators, No hazardous tripping, Comprehend.
  • Convenient: Usage for all application in medium voltage, Compact Dimensions.
  • Easy to integrate into any Panel, Easy to operate, Well suited for retrofit.
  • Limited Maintenance
  • Extremely resistant to harsh environment due to embedded pole construction: Robust Construction: High mechanical stability versus Vibration, Altitude and Temperature.
  • Environmentally Friendly with no harmful gas or oil interrupting media.